| Sec. |
Page |
Item |
Description |
Posted |
Link |
| Disclaimer |
2 |
4th Paragraph |
Paragraph 4, Change to read: “The appendixes are provided as additional resources to the manufacturer, design professional, educator, user, or certifying organization. Appendix A is only part of the standards when referenced. Appendix B is not part of the standards.” |
8/5/2011 |
|
| Disclaimer |
2 |
5th Paragraph |
Add new paragraph after paragraph 5: “This Architectural Woodwork Standard includes citations and quotes from other industry Standards that are neither developed nor published by the Sponsor Associations. The reference to and usage of is not a validation of these citations and quotations outside the context of the AWS. Only when these citations and partial quotations are applied in concert with all other related provisions of this Architectural Woodwork Standard are these citations and partial quotations recognized for application to architectural woodwork.” |
8/5/2011 |
|
| Disclaimer |
2 |
6th Paragraph |
Change to read: “. . . standards, it shall be brought to the attention of the Joint Standards Committee (JSC) by way of the AWS Improvement Suggestion Form (found on page 10 of the AWS) and until specifically addressed, the least restrictive requirement shall prevail.” |
8/5/2011 |
|
| User Guide |
6 |
3rd Paragraph |
Change to read: "These standards are both a voluntary and a definitive document, intended to spell out the requirements for satisfactory performance when referenced as part of contract documents. Sections in the document are interrelated and are intended to be used together, not in part. For example, if a project specification requires compliance with Section10, then compliance with the Preface; the Product (Items 2 - 4), Execution(Items 5 & 6), and Compliance (Item 7) portions of Sections 1-5; along with referenced portions of Appendix A and the Glossary are also required, as applicable. The Introduction, Table of Contents, Suggestion Form, General (Item1) portions of Sections 1-12, and Appendix B are not part of these standards for compliance purposes." |
6/15/2010 |
|
| User Guide |
6 |
3rd Paragraph |
Overwriting previous Errata dated 6/15/2010, change to read: “These standards are both a voluntary and a definitive document, intended to spell out the requirements for satisfactory performance when referenced as part of contract documents. Sections in the document are interrelated and are intended to be used together, not in part. For example, if a project specification requires compliance with Section 10, then compliance with 1-5 along with Appendix A and the Glossary are also required, as applicable. The Introduction, Table of Contents, Suggestion Form, and Appendix B are not part of these standards for compliance purposes.” |
9/10/2010 |
|
| User Guide |
7 |
10th Paragraph |
Change to read: “. . . below, or listed subsequently, creating a columnar effect.” |
8/5/2011 |
|
| Suggestion Form |
10 |
New |
The following email addresses are provided for each of the sponsor Associations:
- AWI – pduvic@awinet.org
- AWMAC – page10s@awmac.com
- WI – AWSsuggestion@woodinst.com
|
6/18/2010 |
 |
| Preface |
25 |
1.4.5 |
Change to read: “The appendixes are provided as additional resources to the manufacturer, design professional, educator, user, or certifying organization. Appendix A is only part of the standards when referenced. Appendix B is not part of the standards.” |
9/10/2010 |
|
| Preface |
25 |
1.4.6 |
Change numbering of Item 1.4.6 to Item 1.4.7 |
8/5/2011 |
|
| Preface |
25 |
1.4.7 |
Change to read: “. . . standards, it shall be brought to the attention of the Joint Standards Committee (JSC) by way of the AWS Improvement Suggestion Form (found on page 10 of the AWS) and until specifically addressed, the least restrictive requirement shall prevail.” |
8/5/2011 |
|
| Preface |
25 |
1.4 |
Add new Item 1.4.6: “This Architectural Woodwork Standard includes citations and quotes from other industry Standards that are neither developed nor published by the Sponsor Associations. The reference to and usage of is not a validation of these citations and quotations outside the context of the AWS. Only when these citations and partial quotations are applied in concert with all other related provisions of this Architectural Woodwork Standard are these citations and partial quotations recognized for application to architectural woodwork.” |
8/5/2011 |
|
| Preface |
28 |
6.3.1.1 |
Shall be Deleted in its entirety. |
1/24/2010 |
|
| 1 |
34 |
1.2.1.2.2.2 |
Change to read: “. . . documentation within the submittal package, requesting . . .” |
6/15/2010 |
|
| 1 |
40 |
4.2.5.2.3 |
Change to read: “CASEWORK, shown in plan, elevation, and section view (section views shall be minimum ½” = 1’-0” (1:20) scale), including:” |
11/11/2011 |
|
| 2 |
44 |
1.2.3.2.1 |
Change to read: “The table and map below (data adapted from USDA Forest Service, Agriculture Handbook) shows . . .” |
2/20/2010 |
|
| 2 |
44 |
1.2.3.2.1 |
In the Table, change the first Geographical Location to read: “Most of U.S. and Canada” |
2/20/2010 |
|
| 2 |
44 |
1.2.3.2.1 |
In the Table, change the second Geographical Location to read: “Damp Southern Coastal areas of the U.S. and Canadian Eastern Coastal Provinces.” |
2/20/2010 |
|
| 2 |
47 |
4.1.2.2.6.1 |
Change to read: “. . . U.S., and Canadian Eastern Coastal Provinces . . .” |
2/20/2010 |
|
| 2 |
47 |
4.1.2.2.7.1 |
Change to read: “. . . U.S., and Canadian Eastern Coastal Provinces . . .” |
2/20/2010 |
|
| 3 |
55 |
4.2a.1 |
Add: “Mahogany, African” |
10/20/2010 |
|
| 3 |
55 |
4.2a.2 |
Change to read: “. . . exceed 1-1/16” (27 mm).” |
12/24/2009 |
|
| 3 |
55 |
4.2a.5 |
Change to read: “. . . it shall mean Honduras or African Mahogany.” |
10/20/2010 |
|
| 3 |
60 |
4.2a.11.3.4 |
Add: “Mahogany, African” |
10/20/2010 |
|
| 4 |
79 |
1.2.31.3 |
Omit second paragraph in its entirety. |
8/5/2011 |
|
| 4 |
79 |
1.2.31.4 |
Change first paragraph to read: “COMBINATION CORE panels are a hybridization of veneer and composition cores offering the advantages of both. Typically these cores have internal layers which are constructed of three or five plies of veneer or a center layer of wafer board (randomly oriented wafers) or other wood fiber which are sandwiched between thin laminations of a composite product like MDF, particleboard, hardboard, etc. Typically these products result in stronger, lighter weight, dimensionally stable panels with increased screw holding ability, and superior surface flatness.” |
9/10/10 |
|
| 4 |
81 |
1.4 |
Add new Item 1.4.3: “COMPOSITION CORE is acceptable, provided it meets or exceeds the performance requirements of ANSI A208.1, Grade M-1.” |
8/5/2011 |
|
| 4 |
81 |
1.4.2 |
Change to read: “COMBINATION CORE is acceptable, provided it meets or exceeds the performance property requirements of ANSIA208-1 or 2." |
9/10/2010 |
|
| 4 |
81 |
1.4.3 |
Change numbering of Item 1.4.3 to Item 1.4.4 |
8/5/2011 |
|
| 4 |
82 |
4.1.4 |
Add new Item 4.1.4.11: “Agrifiber – shall meet or exceed the performance requirements of ANSI A208.1, Grade M-1.” |
8/5/2011 |
|
| 4 |
82 |
4.1.4 |
Add new Item 4.1.4.12: “Combination Core – shall meet or exceed the performance requirements of ANSI A208.1 and/or 2.” |
8/5/2011 |
|
| 4 |
82 |
4.1.4.8 |
Change to read: “. . . ANSI A208.1 . . .” |
8/5/2011 |
|
| 4 |
83 |
4.1.10.1 |
Change to read: “A single component in “AA” Face Grade.” |
12/24/2009 |
|
| 4 |
83 |
4.1.10.2 |
Change to read: “The split-heart method in Face Grades “A-D”, and:” |
12/24/2009 |
|
| 4 |
84 |
4.2a.14.1 |
Change the word at the end of the 7th sentence to read “the manufacturer”. |
6/15/2010 |
|
| 5 |
111 |
4.1.7 |
Change to read: “PANELING requires:” |
6/15/2010 |
|
| 5 |
111 |
4.1.9 |
Change to read: “DOORS require all four faces to be finished and the top/bottom edges, and hardware preparation areas at hinges and lock edges to be sealed.” |
7/29/2010 |
|
| 5 |
111 |
4.1.10 |
Change to read:"CASEWORK requires all exposed exterior, exposed interior and semi-exposed . . ." |
9/2/2011 |
|
| 5 |
111 |
4.1.11.4 |
Change to read: “MOISTURE EXPOSURE EFFECTS such as raised grain or blue stain shall be removed.” |
2/20/2010 |
|
| 5 |
112 |
4.1.11.6.1 |
Change to read: “. . . 72” (1830 mm)” |
6/15/2010 |
|
| 5 |
112 |
4.1.11.7.1 |
Change to read: “. . . 72” (1830 mm)” |
6/15/2010 |
|
| 5 |
112 |
4.1.11.9.1 |
Change to read: “. . . 72” (1830 mm)” |
6/15/2010 |
|
| 5 |
113 |
4.1.12.1 - 4 |
Omit in their entirety. |
11/11/2011 |
|
| 5 |
115 |
4.3.15.2.2.3 |
Change bullet from Economy to Premium column. |
8/5/2011 |
|
| 5 |
116 |
4.3.15.3.1.4 |
Change to read: 4.3.15.3.1.3 |
6/15/2010 |
|
| 5 |
116 |
4.3.15.3.1.5 |
Change to read: 4.3.15.3.1.4 |
6/15/2010 |
|
| 5 |
116 |
4.3.15.3.1.2 |
Add bullet to the Premium column. |
6/15/2010 |
|
| 5 |
116 |
4.3.15.3.1.3 |
Add bullet to the Premium column. |
6/15/2010 |
|
| 5 |
116 |
4.3.15.3.1.4 |
Add bullet to the Premium column. |
6/15/2010 |
|
| 5 |
116 |
4.3.15.5.1.3 |
Add bullet to the Premium column. |
6/15/2010 |
|
| 5 |
116 |
4.3.15.5.1.4 |
Add bullet to the Premium column. |
6/15/2010 |
|
| 6 |
132 |
4.2.9 |
Change vertical text to read: “Exposed Surfaces” |
6/15/2010 |
|
| 6 |
133 |
4.2.9 |
Change vertical text to read: “Exposed Surfaces” |
6/15/2010 |
|
| 6 |
133 |
4.2.12.1.2 |
Omit bullet in Premium Grade column |
11/11/2011 |
|
| 6 |
134 |
4.2.13.1 |
Change to read:

|
8/5/2011 |
 |
| 6 |
134 |
4.2.13.3 |
Change to read: ". . . in thickness." |
9/2/2011 |
|
| 6 |
134 |
4.2.13.3.1 |
Change Item number to new: "4.2.13.4" |
9/2/2011 |
|
| 6 |
134 |
4.2.13.4 |
Change to read: ". . . thickness to be different than this standard." |
9/2/2011 |
|
| 6 |
134 |
4.2.13.4 |
Make this applicable to all Grades. |
9/2/2011 |
|
| 6 |
134 |
4.2.14.1 |
Change to read:
 |
8/5/2011 |
 |
| 6 |
135 |
4.2.15.2.1.2 |
Omit: “Ponderosa Pine”. |
8/5/2011 |
|
| 6 |
135 |
4.2.15.2.1.3 |
Add: “Ponderosa Pine and Sugar Pine”. |
8/5/2011 |
|
| 6 |
139 |
4.4.1.8.1.1 |
Change to read: “0.015” (0.38 mm)” |
6/25/2010 |
|
| 6 |
139 |
4.4.1.8.1.2 |
Change to read: “0.010” (0.25 mm)” |
6/25/2010 |
|
| 6 |
139 |
4.4.1.8.1.3 |
Change to read: “0.005” (0.13 mm)” |
6/25/2010 |
|
| 6 |
141 |
4.4.1.13.3.2 |
Change bullet from Custom to Premium column. |
7/29/2010 |
|
| 6 |
141 |
4.4.1.13.3.3 |
Change bullet from Premium to Custom column. |
7/29/2010 |
|
| 6 |
149 |
6.1.10.3 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 7 |
162 |
4.4.1.7.1.1 |
Change to read: “0.015” (0.38 mm)” |
6/25/2010 |
|
| 7 |
162 |
4.4.1.7.1.2 |
Change to read: “0.010” (0.25 mm)” |
6/25/2010 |
|
| 7 |
162 |
4.4.1.7.1.3 |
Change to read: “0.005” (0.13 mm)” |
6/25/2010 |
|
| 7 |
164 |
4.4.1.12.3.2 |
Change bullet from Custom to Premium column. |
7/29/2010 |
|
| 7 |
164 |
4.4.1.12.3.3 |
Change bullet from Premium to Custom column. |
7/29/2010 |
|
| 7 |
168 |
6.1.10.3 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 8 |
181 |
1.2.12.3 |
Drawings are missing lines, see attached pdf for corrected drawings. See attached pdf. |
4/12/2010 |
 |
| 8 |
182 |
1.4.3 |
Change to read: “FURRING, when required, shall be in accordance with Section 803.11.1 of the International Building Code (IBC), which currently. . . . . “ |
1/24/2010 |
|
| 8 |
187 |
4.2.11.6.1 |
Change to read: “Shall be of CONSTRUCTION STANDARD of the panel manufacturer and conform to the requirements of all applicable labeling agencies.” (NOTE, this item number was previous corrected by Errata on 12/24/09) |
4/12/2010 |
|
| 8 |
187 |
4.2.11.6.2 |
Omit in its entirety. (NOTE, this item number was previous corrected by Errata on 12/24/09) |
4/12/2010 |
|
| 8 |
187 |
4.2.12++ |
Change the first Item 4.2.12 at the top of the page (continued from page 186) and all of the sub-items thereafter) to 4.2.11 and 4.2.11+. |
12/24/2009 |
|
| 8 |
189 |
4.2.13.5.3 |
Change to read: “. . . minimum of 0.018: (0.5 mm) . . .“ |
8/5/2011 |
|
| 8 |
191 |
4.4.1.8.1.1 |
Change to read: “0.015” (0.38 mm)” |
6/25/2010 |
|
| 8 |
191 |
4.4.1.8.1.2 |
Change to read: “0.010” (0.25 mm)” |
6/25/2010 |
|
| 8 |
191 |
4.4.1.8.1.3 |
Change to read: “0.005” (0.13 mm)” |
6/25/2010 |
|
| 8 |
194 |
4.4.6.5.3.2 |
Change bullet from Custom to Premium column. |
7/29/2010 |
|
| 8 |
194 |
4.4.6.5.3.3 |
Change bullet from Premium to Custom column. |
7/29/2010 |
|
| 8 |
200 |
6.1.16.3 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 8 |
200 |
6.2.1.2 |
Change to read: “PANELS shall be installed as specified.” |
10/20/2010 |
|
| 8 |
201 |
6.2.4.2.3 |
Change to read: “. . . every 120” (3048 mm) in . . .” |
6/25/2010 |
|
| 9 |
206 |
1.2.3 |
Change to read: “Specific methods of construction for flush, EXCLUDING HOLLOW CORE, and stile and rail doors illustrated in this section may not represent all types available.” |
8/5/2011 |
|
| 9 |
207 |
1.2.8.2.1 |
Omit in its entirety. |
4/12/2010 |
|
| 9 |
211 |
Entire Page |
In the CD Rom version of the AWS, Page 211 did not print correctly, the attached pdf is how it should look. |
12/24/2009 |
 |
| 9 |
212 |
Entire Page |
In the CD Rom version of the AWS, Page 212 did not print correctly, the attached pdf is how it should look. |
12/24/2009 |
 |
| 9 |
212 |
1.2.18.4.1.1 |
Change the word “engineered” to “high density” |
4/12/2010 |
|
| 9 |
212 |
1.2.18.4.1.1 |
Overwriting previous Errata dated 4/12/2010, remove the wording “high-density” |
9/10/10 |
|
| 9 |
212 |
1.2.18.4.2.2 |
Change the word “engineered” to “high density” |
4/12/2010 |
|
| 9 |
212 |
1.2.18.4.2.2 |
Overwriting previous Errata dated 4/12/2010, remove the wording “high-density” |
9/10/10 |
|
| 9 |
214 |
1.2.18.5.5 |
At the drawing, for the text “Rail” the line is incorrectly pointing to the core not the top rail as intended. |
12/24/2009 |
|
| 9 |
215 |
1.2.18.5.7 |
At the drawing, for the second text of “Cross Band” the line is incorrectly pointing to the same item as the first “Cross Band” reference and was intended to be pointing at the cross band layer immediately below the face veneer.. |
12/24/2009 |
|
| 9 |
216 |
1.2.18.8 |
Change to read: “. . . otherwise. As in all veneer matching, veneer length availability should be taken into consideration. – see examples below:” |
4/12/2010 |
|
| 9 |
222 |
4.1.2 |
Change to read: “IN LIEU OF TESTING for WDMA TM-7 (Slam Cycle) & TM-8 (Hinge Loading), compliance . . .” |
9/10/2010 |
|
| 9 |
222 |
4.1.2 |
Add new Item 4.1.2.1: “Composite cross bands shall have minimum 55 lbs (24.9 kgs) density.” |
8/5/2011 |
|
| 9 |
222 |
4.1.2.1 |
Omit in its entirety. |
7/29/2010 |
|
| 9 |
222 |
4.1.2.3.3 |
Change to read: “Minimum 1” (25.4 mm) hardwood or material that has been qualified in accordance with WDMA TM 15 (latest edition) stiles and rails.” |
9/2/2011 |
|
| 9 |
224 |
4.1.19.1 |
Change to read: “. . . bundled in appropriately labeled sets or pre-fit and tacked in the appropriate light opening, and:” |
12/24/2009 |
|
| 9 |
224 |
4.1 |
Add new Item: “4.1.21: DOORS require all four faces to be finished and the top/bottom edges, and hardware preparation areas at hinges and lock edges to be sealed.” |
7/29/2010 |
|
| 9 |
226 |
4.2.6.1.2.11 |
At the Natural Characteristic - Mineral Streaks for AA Grade, change allowance to read: “No: at Maple, Slight” |
11/11/2011 |
|
| 9 |
231 |
4.2.6.2 |
Change the word “engineered” to “high density” |
4/12/2010 |
|
| 9 |
231 |
4.2.6.2 |
Overwriting previous Errata dated 4/12/2010, remove the wording “high-density” |
9/10/2010 |
|
| 9 |
231 |
4.3.1.2 |
Change to read: “. . . backing or material that has been qualified in accordance with WDMA TM 15 (latest edition).” |
9/2/2011 |
|
| 9 |
231 |
4.3.2 |
In the first cell, remove the asterisk so it reads: “Minimum WDMA PERFORMANCE DUTY VALUES – Reprinted . . .” - In the sixth cell down add an asterisk (*) so that it reads: “Door Finish, Various ASTM test methods * “ |
12/24/2009 |
|
| 9 |
232 |
4.3.6 |
Change to read: “. . . out on both sides, and/or:” |
6/15/2010 |
|
| 9 |
232 |
4.3.6.2 |
Change to read: “Use of glazing gaskets, tape or high density foam is acceptable.” |
6/15/2010 |
|
| 9 |
233 |
4.3.8.8.1.1 |
Change to read: “0.010” (0.25 mm)” |
6/25/2010 |
|
| 9 |
233 |
4.3.8.8.1.2 |
Change to read: “0.005” (0.13 mm)” |
6/25/2010 |
|
| 9 |
233 |
4.3.8 |
Add new Item: 4.3.8.13
 |
1/24/2010 |
 |
| 9 |
233 |
4.3.8.13.3.2 |
Change bullet from Custom to Premium column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 9 |
233 |
4.3.8.13.3.3 |
Change bullet from Premium to Custom column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 9 |
235 |
4.3.9.6.2.1 |
Change to read: “Permit one FINGER JOINT at each edge . . .” |
8/5/2011 |
|
| 9 |
235 |
4.3.9.6.2.1 |
Change to read: “. . . a distance of 48” (1219 mm).” |
12/24/2009 |
|
| 9 |
236 |
4.3.10.7.3 |
Change to read: “GRAIN shall run vertically.” |
6/15/2010 |
|
| 9 |
239 |
6.1.13.2 |
Change to read: “Clearance at the bottom of fire-rated doors shall conform to NFPA 80 and at non-rated doors shall be a minimum of 1/4” and a maximum of 5/8” measured from the bottom of the door to the highest point of the finish floor that the door swings over.” |
9/10/10 |
|
| 9 |
239 |
6.1.14.2.5 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 10 |
245 |
1.2.10.1.4 |
Change to read: “. . . shelves, cleats and nailers.” |
8/5/2011 |
|
| 10 |
246 |
1.2.11.1 |
Change to read: “Tops and bottoms of shelves, including front edge banding.” |
8/5/2011 |
|
| 10 |
248 |
1.2.14.2.2.2.1 |
Change to read: “. . . compatible to exposed exterior surface in color . . .” |
10/06/2010 |
|
| 10 |
249 |
Entire Page |
In the CD Rom version of the AWS, Page 249 did not print correctly, the attached pdf is how it should look. |
12/24/2009 |
 |
| 10 |
251 |
1.2.18.3 |
Change to read: “. . . TYPE A or B casework, except:” |
4/02/2013 |
|
| 10 |
251 |
1.2.18.3 |
Add new Item 1.2.18.3.1: “At EXPOSED KNUCKLE HINGES, defaulting to REVEAL OVERLAY is at the option of the manufacturer, and:” |
4/02/2013 |
|
| 10 |
251 |
1.2.18.3 |
Add new Item 1.2.18.3.1.1: “If reveal overlay the reveal shall be determined by the hinge overlay.” |
4/02/2013 |
|
| 10 |
252 |
1.2.19.2.3.1 |
Change to read: “. . . match VERTICALLY and HORIZONTALLY within . . .” |
8/5/2011 |
|
| 10 |
252 |
1.2.19.2.3.2 |
Change to read: “. . . be well-matched for color and grain across . . .” |
8/5/2011 |
|
| 10 |
253 |
1.2.21.2.1 |
Change to read: “50 lbs per sq ft (244.1 kg/m2) for . . .” |
12/24/2009 |
|
| 10 |
253 |
1.2.21.2.2 |
Change to read: “40 lbs per sq ft (195.3 kg/m2) for . . .” |
12/24/2009 |
|
| 10 |
257 |
1.5.6.2.2 |
Change Item # to read: “1.5.6.1.1” |
12/24/2009 |
|
| 10 |
257 |
1.5.6.2.2.1 |
Change Item # to read: “1.5.6.1.1.1” |
12/24/2009 |
|
| 10 |
258 |
3.1 |
Change to read: “. . . Sections 3 and 4, except:” |
4/2/2013 |
|
| 10 |
258 |
3.1 |
Add new Item 3.1.1: “At EXPOSED KNUCKLE HINGES, defaulting to REVEAL OVERLAY is at the option of the manufacturer, and:” |
4/2/2013 |
|
| 10 |
258 |
3.1 |
Add new Item 3.1.1.1: “If reveal overlay the reveal shall be determined by the hinge overlay.” |
4/2/2013 |
|
| 10 |
258 |
4.1.8.1.1 |
Change to read: “. . . test requirements, with minimum 120 degree opening capacity. |
12/8/2011 |
|
| 10 |
259 |
New-4.1.8.1.5 |
Add new Item 4.1.8.1.5 which reads: "Hinges shall have a minimum 120 degree of opening capacity" |
2/9/2012 |
|
| 10 |
260 |
4.1.8 |
Add new Item: “4.1.8.11: Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 10 |
260 |
4.1.8.11 |
Change to read: “INSTALLED per manufacturers recommendations and . . .” |
8/5/2011 |
|
| 10 |
260 |
4.1.19 |
Remove the dot from Custom Grade; this is only applicable to Premium Grade. |
6/15/2010 |
|
| 10 |
260 |
4.1.20.1.4 |
Change to read: “. . . shelves, cleats and nailers.” |
8/5/2011 |
|
| 10 |
261 |
4.1.20.2.3 |
In the first sentence, remove the wording: “(even in a bank of drawers)” |
7/29/2010 |
|
| 10 |
261 |
4.1.21.1 |
Change to read: “Tops and bottoms of shelves, including front edge banding.” |
8/5/2011 |
|
| 10 |
261 |
4.2.1.2 |
Change to read: “. . . match VERTICALLY and HORIZONTALLY within . . .” |
8/5/2011 |
|
| 10 |
261 |
4.2.1.2.2 |
Change to read: “. . . be well-matched for color and grain across . . .” |
8/5/2011 |
|
| 10 |
263 |
4.2.7.3.1 |
Change to read: “. . . WOOD, mill option with manufacturer’s choice of species, or . . .” |
11/11/2011 |
|
| 10 |
263 |
4.2.7.3.2 |
Change to read: “. . . WOOD, minimum HPVA GRADE C of manufacturer’s species choice, or . . .” |
11/11/2011 |
|
| 10 |
263 |
4.2.7.3.3 |
Change to read: “. . . WOOD, minimum HPVA GRADE C of compatible . . .” |
11/11/2011 |
|
| 10 |
263 |
4.2.7.3.3.1 |
Change to read: “. . . prefinished hardwood lumber or 7- or 9- . . .” |
6/15/2010 |
|
| 10 |
263 |
4.2.7.3.3.2 |
Change to read: “. . . prefinished hardwood lumber or 7- or 9- . . .” |
6/15/2010 |
|
| 10 |
263 |
4.2.8.2.2 |
Change to read: “. . . compatible to exposed exterior surface in color . . .” |
10/6/2010 |
|
| 10 |
264 |
4.2.8.3.2.1.2 |
Change to read: “. . . (15.9 mm) for drawers up to 30” (762 mm) wide and ¾” (19 mm) for drawers over 30” (762 mm) wide. |
6/15/2010 |
|
| 10 |
265 |
4.4.1.3.1.1 |
Change to read: “0.015” (0.38 mm)” |
03/08/2010 |
|
| 10 |
265 |
4.4.1.3.1.2 |
Change to read: “0.010” (0.25 mm)” |
03/08/2010 |
|
| 10 |
265 |
4.4.1.3.1.3 |
Change to read: “0.005” (0.13 mm)” |
03/08/2010 |
|
| 10 |
266 |
4.4.2 |
Change to read: “Fixed HORIZONTAL cabinet members, including tops and bottoms, shall be either flush or set back a maximum of 1/16” (1.6 mm) at their intersection with vertical members and shall be uniform throughout the room. |
12/24/2009 |
|
| 10 |
267 |
4.4.4.3 |
Change to read: “When visible from above, the TOP EDGE of the cabinet ends shall be edgebanded to match the exposed exterior surface.” |
9/10/10 |
|
| 10 |
268 |
4.4.5.11.1 |
Change to read “. . . locked position, or:” |
6/15/2010 |
|
| 10 |
268 |
4.4.5.11.1 |
Add new Item “4.4.5.11.1.1: STRIKES are required.” |
6/15/2010 |
|
| 10 |
268 |
4.4.5.11.2 |
Change to read: “STRIKES are required at spring loaded latches.” |
6/15/2010 |
|
| 10 |
268 |
4.4.5.14.5.1 |
Change to Item 4.4.5.14.6 |
6/15/2010 |
|
| 10 |
269 |
4.4.6.4 |
Change to read: “. . .in width and 84” (2134 mm) in height.” |
12/24/2009 |
|
| 10 |
269 |
4.4.6.7 |
Change to read: "Core to be of an approved particleboard or medium-density fiberboard." |
08/29/2012 |
|
| 10 |
269 |
4.4.6.8.1 |
Change to read “. . . locked position, or:” |
6/15/2010 |
|
| 10 |
269 |
4.4.6.8.1 |
Add new Item “4.4.6.8.1.1: STRIKES are required.” |
6/15/2010 |
|
| 10 |
269 |
4.4.6.8.2 |
Change to read: “STRIKES are required at spring loaded latches.” |
6/15/2010 |
|
| 10 |
270 |
4.4.6.9.2.6 |
Change to read: “WRAP AROUND hinges, at flush overlay construction, shall . . . be let” |
4/2/2013 |
|
| 10 |
274 |
4.4.8.9 |
Change to read: “. . . shall be installed with concealed fasteners.” |
12/24/2009 |
|
| 10 |
274 |
4.4.9.2.3 |
Change to read: “. . . EDGES of the cabinet ends . . .” |
6/18/2010 |
|
| 10 |
274 |
4.4.9.2.3 |
Eliminate the indicator “dot” at Custom Grade |
6/18/2010 |
|
| 10 |
274 |
4.4.9.2.3 |
Add new Item 4.4.9.2.3.1 “EXPOSED EDGES of cabinet ends shall be banded with material compatible to the exposed faces.” And show an indicator “dot” for Custom Grade only. |
6/18/2010 |
|
| 10 |
274 |
4.4.9.2.8 |
Change to read: “If CABINET ENDS Extend . . .” |
6/18/2010 |
|
| 10 |
274 |
4.4.9.2.8 |
Eliminate the indicator “dot” at Custom Grade |
6/18/2010 |
|
| 10 |
274 |
4.4.9.2.8 |
Add new Item 4.4.9.2.8.1 “If CABINET ENDS EXTEND below the bottom, the interior exposed surface of the end shall be of material compatible to the exposed surface.” And show an indicator “dot” for Custom Grade only. |
6/18/2010 |
|
| 10 |
274 |
4.4.9.3.2.1 |
Change to read: “CABINET END shall be BANDED to match other exposed surfaces.” |
6/18/2010 |
|
| 10 |
275 |
4.4.12 |
Add new item “4.4.12.11: Visible joints are not permitted at exposed interior or semi-exposed interior cabinet backs.” |
6/15/2010 |
|
| 10 |
275 |
4.4.12.8 |
Delete in its entirety along with its three subordinates. |
10/6/2010 |
|
| 10 |
275 |
4.4.13.2 |
Eliminate in its entirety |
6/18/2010 |
|
| 10 |
275 |
4.4.13.5 |
Change to read: “. . . at separate toes at a maximum of 48” (1219 mm) on . . .” |
6/15/2010 |
|
| 10 |
275 |
4.4.13.6 |
Change to read: “If specified to have a MOISTURE-RESITANT BASE, all base components shall be any material complying with the BASE CABINET SUBMERSION TEST, as explained in APPENDIX A.” |
8/5/2011 |
|
| 10 |
276 |
4.4.13 |
Add new Item “4.4.13.8: MOVEBALE TOES at ADA base cabinets shall not have a vertical gap exceeding that allowable for the doors above.“ |
6/15/2010 |
|
| 10 |
276 |
4.4.14.7 |
Change to read: “. . . (1829 mm) high not immediately abutting a structural wall or another cabinet at both ends, require . . .” |
10/12/2011 |
|
| 10 |
276 |
4.4.14.9.2 |
Change to read: “CORES to be subject to 40 lbs per sq ft (195.3 kg/m2) load . . .” |
12/24/2009 |
|
| 10 |
276 |
4.4.14.9.3 |
Change to read: “With a 50 lbs per sq ft (244.1 kg/m2) load . . .” |
12/24/2009 |
|
| 10 |
277 |
4.4.14.10.1.6.1 |
Change to read: “50 lbs per sq ft (244.1 kg/m2) for . . .” |
12/24/2009 |
|
| 10 |
277 |
4.4.14.10.1.6.2 |
Change to read: “40 lbs per sq ft (195.3 kg/m2) for . . .” |
12/24/2009 |
|
| 10 |
281 |
4.4.18.4.1 |
Add bullet for Economy Grade only. |
10/6/2010 |
|
| 10 |
281 |
4.4.20.4.2 |
Change to read: “EXPOSED FASTENERS are NOT permitted at EXPOSED EXTERIOR surfaces.” |
10/12/2011 |
|
| 10 |
282 |
4.4.20 |
Add new Item 4.4.20.9: “Joinery by other than the above requirements is permitted, provided it has been independently tested to show compliance to the Wall Cabinet Structural Integrity Test as shown in Appendix A.” |
2/20/2010 |
|
| 10 |
282 |
4.4.20.6.3 |
Change to read: “. . . (49.3 mm) . . .” |
6/15/2010 |
|
| 10 |
282 |
4.4.20.6.4 |
Change to read at two occurrences: “1-15/16” (49.3 mm) MAX.” |
6/15/2010 |
|
| 10 |
282 |
4.4.20.7.2 |
Change to read: “. . . (49.3 mm) . . .” |
6/15/2010 |
|
| 10 |
282 |
4.4.20.7.5 |
Change to read at two occurrences: “1-15/16” (49.3 mm) MAX.” |
6/15/2010 |
|
| 10 |
282 |
4.4.20.8.1 |
Change to read: “. . . minimum #20 or . . .” |
6/15/2010 |
|
| 10 |
282 |
4.4.21.3.1 |
Change to read: SCRIBE MOLDS are not permitted. |
1/24/2010 |
|
| 10 |
283 |
4.4.22.1 |
Change to read: “. . . (38 mm) . . .” |
6/15/2010 |
|
| 10 |
283 |
4.4.22.2 |
Change to read: “. . . (38 mm) . . .” |
6/15/2010 |
|
| 10 |
283 |
4.4.23.1 |
Change to read: “AT DOORS and DRAWERS, EDGE alignment . . .” |
3/08/2010 |
|
| 10 |
284 |
4.4.23.3.5 |
Change to read: “DOORS and DRAWERS shall be on the same plane as one another and shall not exceed:” |
3/08/2010 |
|
| 10 |
284 |
4.4.23.3.5 |
Add new Item 4.4.23.3.5.1: “1/8” (3.18 mm)” with indicator for Economy Grade |
3/08/2010 |
|
| 10 |
284 |
4.4.23.3.5 |
Add new Item 4.4.23.3.5.2: “1/16” (1.59 mm)” with indicator for Custom Grade |
3/08/2010 |
|
| 10 |
284 |
4.4.23.3.5 |
Add new Item 4.4.23.3.5.3: “1/32” (0.79mm)” with indicator for Premium Grade |
3/08/2010 |
|
| 10 |
285 |
4.4.25.2.4.1 |
Change to read: “Be BANDED at all four edges, except:” |
8/5/2011 |
|
| 10 |
285 |
4.4.25.2.4.1 |
Add new Item 4.4.25.2.4.1.2 “When back-beveled.” |
8/5/2011 |
|
| 10 |
285 |
4.4.25.2.4.1 |
Add new Item 4.4.25.2.4.1.1 “When of solid wood.” |
8/5/2011 |
|
| 10 |
285 |
4.4.25.4.4 |
Change to read: “. . . metal dowel screwed, pocket-screwed, or biscuit-joined, and:” |
6/15/2010 |
|
| 10 |
286 |
4.4.26 |
Add new Item: 4.4.26.4
 |
1/24/2010 |
 |
| 10 |
286 |
4.4.26.1.2 |
Change to read: “. . . minimum of 0.018: (0.5 mm) . . .“ |
8/5/2011 |
|
| 10 |
286 |
4.4.26.4.3.2 |
Change bullet from Custom to Premium column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 10 |
286 |
4.4.26.4.3.3 |
Change bullet from Premium to Custom column. (NOTE, this item number was previous established by Errata on 0/24/10) |
7/29/2010 |
|
| 10 |
288 |
6.1.5.1 |
Change to read: “. . . flush joint tolerances as set forth in these standards. |
3/08/2010 |
|
| 10 |
290 |
6.1.10.4 |
Add bullet for Premium Grade |
12/8/2011 |
|
| 10 |
290 |
6.1.11 |
Change to read: “Exposed fasteners are NOT permitted at exposed exterior surfaces, except . . .” |
10/20/2010 |
|
| 10 |
291 |
6.1.12.3.2 |
Eliminate in its entirety. |
10/20/2010 |
|
| 10 |
292 |
6.1.12.3.3 |
Change to read: “At EXPOSED INTERIOR surfaces, cover caps of compatible color to interior are required.” |
10/20/2010 |
|
| 10 |
292 |
6.1.12.3.3 |
Add bullet to Custom column |
10/20/2010 |
|
| 10 |
292 |
6.1.12.4.2 |
Change to read: “At EXPOSED INTERIOR surfaces, cover caps of compatible color to interior are required.” |
10/20/2010 |
|
| 10 |
292 |
6.1.12.5.3 |
Change to read: “. . . end and equally spaced.” |
8/5/2011 |
|
| 10 |
292 |
6.1.12.6.1 |
Change to read: “Separate bases or toes are required to be mechanically fastened in the field to the cabinet bottom with flat-head screws set flush or slightly recessed, to prevent their movement.” |
6/18/2010 |
|
| 10 |
293 |
6.1.18.3 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 10 |
|
Special Notice |
"Projects specified to be in compliance with the Woodwork Institute’s Manual of Millwork for Laboratory Grade and falling under the purview the Architectural Woodwork Standards (AWS) shall meet all of the AWS requirements for Premium Grade plus the following additional requirements (from the 11th Edition, Manual of Millwork):
- a) Interior cabinet surfaces shall conform to SEFA's, 1-hour exposure chemical resistance test procedures as explained in Appendix A, Page 349 of the AWS.
- b) Toe kicks shall be any material complying with the Base Cabinet Submersion Test, as explained in Appendix A, Page 372 of the AWS.
- c) Components within 2" of the finished floor shall be constructed of solid lumber, exterior plywood, or exterior particleboard.
- d) At base cabinets, backs shall be removable.
|
2/20/2010 |
|
| 11 |
296 |
1.2.3 |
Add new Item 1.2.3.2: “The exposed underside surface over 42” (1067 mm) off the finish floor.” |
8/5/2011 |
|
| 11 |
299 |
1.2.10.5.1 |
At ASSEMBLY 2, add vertical line at furthest right hand detail to complete edge banding illustration. |
8/5/2011 |
|
| 11 |
299 |
Entire Page |
In the CD Rom version of the AWS, Page 299 did not print correctly, the attached pdf is how it should look. |
2/20/2010 |
 |
| 11 |
299 |
1.2.10.5.1 |
Change Item number to: 1.2.11.5.1 |
12/12/2012 |
|
| 11 |
302 |
1.3.5.1 |
Change to read: "... 5.5% or less is required." |
12/12/2012 |
|
| 11 |
303 |
3.4 |
Change “. . . CUSTOM GRADE . . . “ to “. . . PREMIUM GRADE . . . “ |
1/24/2010 |
|
| 11 |
304 |
4.2.4.1 |
Add new Item 4.2.4.1.1: “At veneer faced, core shall be a minimum of ¾” (19 mm) particleboard, medium-density fiberboard, veneer core or otherwise approved engineered core, and:” |
1/24/2013 |
|
| 11 |
304 |
At New 4.2.4.1 |
Add new Item 4.2.4.1.1.1: “At SINK TOPS and their splashes, use of veneer core plywood with Type II adhesive, industrial-grade particleboard or fiberboard with a 24-hour thickness swell factor of 5.5% or less, and a 24-hour water-absorption factor of 10% or less is required.” |
1/24/2013 |
|
| 11 |
304 |
4.2.5.1 |
Change to read: “Shall be HPDL, a minimum of .039” (0.99 mm) in thickness.” |
3/08/2010 |
|
| 11 |
304 |
4.2.5.1.1 |
Omit in its entirety. |
3/08/2010 |
|
| 11 |
305 |
4.2.5.3.1 |
Change to read: "... swell factor of 5.5% or less is required . . ." |
9/2/2011 |
|
| 11 |
307 |
4.4.7 |
Add new Item after 4.4.7: “BACK SPLASHES require end splashes at wall ends.” With bullets in the Custom and Premium Grade columns. |
11/11/2011 |
|
| 11 |
308 |
4.4.14.1 |
Change to read: “. . . (see Test D and Test H illustrations in COMPLIANCE) . . . “ |
3/08/2010 |
|
| 11 |
308 |
4.4.14.1.1 |
Change to read: “0.030” (0.76 mm)” |
3/08/2010 |
|
| 11 |
308 |
4.4.14.1.2 |
Change to read: “0.020” (0.51 mm)” |
3/08/2010 |
|
| 11 |
308 |
4.4.14.1.3 |
Change to read: “0.005” (0.13 mm)” |
3/08/2010 |
|
| 11 |
309 |
4.4.15.1.1 |
Change to read: “0.015” (0.38 mm)” |
6/25/2010 |
|
| 11 |
309 |
4.4.15.1.2 |
Change to read: “0.010” (0.25 mm)” |
6/25/2010 |
|
| 11 |
309 |
4.4.15.1.3 |
Change to read: “0.005” (0.13 mm)” |
6/25/2010 |
|
| 11 |
310 |
4.4.15 |
Add new Item: 4.4.15.19
 |
1/24/2010 |
 |
| 11 |
310 |
4.4.15.13 |
Omit in its entirety. |
11/11/2011 |
|
| 11 |
310 |
4.4.15.19.3.2 |
Change bullet from Custom to Premium column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 11 |
310 |
4.4.15.19.3.3 |
Change bullet from Premium to Custom column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 11 |
315 |
6.1.12.1 |
Change to read: “. . . WOOD and HPDL to HPDL shall . . .” |
6/25/2010 |
|
| 11 |
315 |
6.1.12.3 |
Change to read: “. . . ELEMENTS, excluding HPDL to HPDL, shall . . .” |
6/25/2010 |
|
| 11 |
316 |
6.1.15.3 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| 11 |
317 |
6.2.2.5.1 |
Change 2nd item number 6.2.2.5.1 to: 6.2.2.5.2 |
12/12/2012 |
|
| 12 |
327 |
4.4.3.6.1 |
Change to read: “0.005” (0.13 mm)” |
6/25/2010 |
|
| 12 |
328 |
4.4.3 |
Add new Item: 4.4.3.10
 |
1/24/2010 |
 |
| 12 |
328 |
4.4.3.10.3.2 |
Change bullet from Custom to Premium column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 12 |
328 |
4.4.3.10.3.3 |
Change bullet from Premium to Custom column. (NOTE, this item number was previous established by Errata on 1/24/10) |
7/29/2010 |
|
| 12 |
332 |
6.1.20.3 |
Change to read: “Installed using all furnished fasteners or fastener provisions and when fastener provisions are countersunk, fasteners shall be countersunk.” |
12/24/2009 |
|
| Appendix A |
340 |
Bldg. Code |
Change “National Uniform Building Code (UBC)” reference to: “International Building Code (IBC)” |
1/24/2010 |
|
| Appendix A |
340 |
Bldg. Code |
Change “(UBC)” reference to: “(IBC)” |
1/24/2010 |
|
| Appendix A |
372 |
Submersion Test |
Change wording under title to read: “. . . specified for moisture resistant or laboratory use)” |
8/5/2011 |
|
| Appendix A |
373 |
Door Hinge Test |
Omit in its entirety. |
8/5/2011 |
|
| Glossary |
382 |
|
Add/insert new term: “CABINET FACE: The outermost surface of a cabinet including doors and/or drawers.” |
11/11/2011 |
|
| Glossary |
384 |
Combination Core |
Change definition to read: “Panels are a hybridization of veneer and composition cores offering the advantages of both. Typically these cores have internal layers which are constructed of three or five plies of veneer or a center layer of wafer board (randomly oriented wafers) or other wood fiber which are sandwiched between thin laminations of a composite product like MDF, particleboard, hardboard, etc. Typically these products result in stronger, lighter weight, dimensionally stable panels with increased screw holding ability, and superior surface flatness.” |
9/10/2010 |
|
| Glossary |
386 |
Add new term |
DOOR FURNISHER: As used in PRODUCT of Section 09, is defined as the party responsible for the take off, ordering and supplying of the doors to a project. |
4/12/2010 |
|
| Glossary |
386 |
Dowel |
Remove the wording: “or a metal screw” |
12/24/2009 |
|
| Glossary |
395 |
Add new term |
NON-WOOD: As used in EXECUTION sections of this standard refers to components made of material other than wood and that are subject to this standard's tolerance threshold values. |
12/24/2009 |
|